Written by Published in Blog

 

Huayi Compressor announces the availability of the complete range of multi-refrigerant units for R452A, R448A, R449A, R454C and R455A for LBP and HMBP aimed to light commercial refrigeration applications.

 

In accordance to F-gas regulation that will be effective from 1st January 2020, HFCs refrigerants like R404A with a GWP of 2500 or more will be banned in hermetically sealed refrigerators and freezers for commercial use.

 

Cubigel Compressors® units are prepared for the use of refrigerants R452A, R448A, R449A, R454C and R455A as replacement, moreover, we are anticipating the next step of the F-Gas for the replacement of R134a to be phased out on 2022, the use of refrigerant R513A y R450A in our units.

 

Huayi Compressor Barcelona has released its position in regards to the alternatives to R404A and R134a. At this moment there are no long-term alternatives to R404A in the market that can meet the F-Gas Regulation after 2022; these new refrigerant blends are only a transitional solution.

 

The company is committed to natural refrigerants (R290 and R600a) as a long-term solution for light commercial refrigeration. HCs are an environmentally friendly, non-toxic, non-ozone-depleting replacement.

 

 

Download brochure
Written by Published in Blog

Huayi Compressor announces the availability of the complete range of multi-refrigerant units for R452A, R448A and R449A for LBP and HMBP aimed to light commercial refrigeration applications.

In accordance to F-gas regulation that will be effective from 1st January 2020, HFCs refrigerants like R404A with a GWP of 2500 or more will be banned in refrigerators and freezers for commercial use.

Cubigel Compressors® units are prepared for the use of refrigerants R452A, R448A and R449A as replacement, moreover, we are anticipating the next step of the F-Gas for the replacement of R134a to be phased out on 2022, the use of refrigerant R513A y R450A in our units.

Based on the test performed by Huayi Compressor Barcelona using the mid-point protocol, R452A showed similar performance to R404A in HMBP conditions and a small decreased performance by around 3% - 8% when tested under LBP conditions.

Huayi Compressor Barcelona has released its position in regards to the alternatives to R404A and R134a. At this moment there are no long-term alternatives to R404A in the market that can meet the F-Gas Regulation after 2022; these new refrigerant blends are only a transitional solution.

The company is committed to natural refrigerants (R290 and R600a) as a long-term solution for light commercial refrigeration. HCs are an environmentally friendly, non-toxic, non-ozone-depleting replacement.

Multi-refrigerant condensing units R404A - R452A - R449A - R448A performance tables

Multi-refrigerant condensing units R134a - R513A - R450A performance tables 

 

Written by Published in Blog

Dear Customer,

At the end of this year all refrigerants with GWP over 2500 will banned in Europe as the first step of the F-Gas regulation that will be completed in 2021 with the prohibition of refrigerants with a GWP over 150. This leads us to an increase of the use of natural refrigerants in the coming years as they are, from our point of view, the definitive solution. On the other hand this year we have had the definitive approval of the IEC standard that allows using up to 500gr of R600a or R290 in a refrigeration system. These are good news for our industry as this was the last obstacle to expand the use of hydrocarbons. We, at Huayi Group, are prepared for it with a wide product range covering all applications, voltages and different efficiency levels.

During 2019 not only we have extended our range of compressors but we have also expanded our range of condensing units. Following our strategy we have strengthening our position in the condensing units business, where we have developed a new version like the Full Liquid Line and we have expanded our capabilities of customized manufacturing condensing units and complete systems. We want to offer to our customers an integrated solution to their needs and help them to meet the requirements of the new regulations.

Written by Published in Blog

Vicente Guilabert, Vice General Manager R + D and QA from Huayi Compressors, gave an interesting presentation at the Tecnofrío’19 Congress that took place in Madrid on October 16 and 17, 2019 that aroused great interest from the light commercial refrigeration sector.

The presentation centered in the impact of the announcement made by the International Electrotechnical Commission last May, which finally approved the new edition of the IEC60335-2-89 standard that, among other things, defines the increase in charge limit for A3 (flammable) refrigerants at 500 gr. from 150 gr., as well as an increase in the charge limit for A2 and A2L (low flammable refrigerants) to 1,200 gr. from 150 gr.